Security, Compliance and Identity. Microsoft Edge Insider. Azure Databases. Autonomous Systems. Education Sector. Microsoft Localization. Microsoft PnP. Healthcare and Life Sciences. Internet of Things IoT. Enabling Remote Work. Small and Medium Business. Event ID: , , , , , Confirm witness accessibility by viewing the quorum configuration of a failover cluster and the status of a witness disk.
When the cluster configuration on a node is missing or corrupt, the Cluster service cannot load the configuration and therefore cannot start. Where possible, the Cluster service will obtain the latest cluster configuration from other nodes in the cluster.
Ensure that other nodes are started. If the only node or nodes that can be started appear to have a missing or corrupt cluster configuration database, you will probably need to restore one of the nodes from a system state backup. For a failover cluster node, the system state backup includes the cluster configuration. Sometimes when the node attempts to unload the cluster configuration database, the action does not fully complete. Try stopping and restarting the Cluster service.
If this does not succeed, restart the operating system on the affected node. Event ID: , , Check DFS namespace configuration. Returns the number of events when encrypted settings for a cluster resource could not be successfully applied to the container on this node. Close any application that might have an open handle to the registry checkpoint indicated by the event.
This will allow the registry key to be replicated as configured with the resource properties. If necessary, contact the application vendor about this problem. You can use a utility called Handle with the -a option to view handles to the registry. You might be able to correct this issue by restarting the Cluster service. Event ID: , , , , , , , , Confirm that the share exists and that the permissions allow access to the share. If possible, determine whether the path to the share has been changed.
If so, recreate the share with the correct name. View all the resources in the clustered file server instance to ensure that they are coming online, and review the dependencies among the resources.
Reconfigure as necessary to correct any problems. Returns the number of events that occur when a generic application could not be brought online during an attempt to create the process due to; the application not being present on this node, an incorrect path name, or an incorrect binary name. Confirm that the following are true for the application used by the clustered Generic Application instance:. Confirm that the correct service is specified in the configuration for the Generic Service resource and confirm that the service is fully installed on all nodes that are possible owners of the resource.
Check the address, subnet, and network properties of the IP Address resource. If the IP Address resource appears to be configured correctly, check the condition of network adapters and other network components used by the cluster. Correct any problems with the physical network adapters and the cluster virtual adapter. If a previous change in the configuration is interfering with the function of the cluster virtual adapter, it might be necessary to reinstall the failover clustering feature on the node.
Also, use the Validate a Configuration Wizard to review the network configuration. Returns the number of events that occur when the node failed to join the failover cluster due to an error. Check and correct any problems with the application or service associated with the resource. Adjust the properties for the resource in the cluster configuration, especially the value for the Pending Timeout for the resource.
This value must allow enough time for the associated application or service to start. Check the state of all resources in the clustered service or application. Returns the number of events that occur when the Cluster service is shutting down because quorum was lost. This can occur when network connectivity is lost between some or all of the nodes in the cluster, or the witness disk fails over.
It can also occur if you make a change in the cluster configuration such as increasing the number of nodes, when the number of nodes currently online is too few to achieve quorum in the new configuration. Also check network devices adapters, cables, hubs, switches, etc. Returns the number of events that occur when the Registry Checkpoint for Cluster resource could not be restored to a registry key.
Returns the number of events that occur when the Failover cluster virtual adapter has lost contact with the process. Use Resource Monitor to determine, in real time, how many system resources a service or application is utilizing. This may take several minutes if the system is critically low on resources.
SolarWinds uses cookies on its websites to make your online experience easier and better. By using our website, you consent to our use of cookies.
Join Tek-Tips Forums! Join Us! By joining you are opting in to receive e-mail. Promoting, selling, recruiting, coursework and thesis posting is forbidden. Students Click Here. Which is currently connected to an MSA storage device via fiber cables. I currently have sql database located on MSA logical for ex.
The G drive is running out of space. I currently installed a much bigger Logical array. The cluster is pointing to the G drive on the MSA. I would like to backup up all the data from the G drive and restore it onto the new logical array of drives. I would to delete the orginal G drive and make the newer logical drive G.